NEW TELECOM & UPS BATTERIES
Due to the rapidly increasing demand for more reliable UPS and standby power in telecommunication and computer networks, a new generation of "longer" life and "high" rate battery power has emerged. To address this market need, GS Battery offers our PWL 'Super Long Life', PXL 'High Rate-Long Life', PX 'High Rate" series of VRLA products.
3. PWL SERIES 'SUPER LONG
LIFE' DISCHARGE VRLA BATTERIES
Through optimization of the chemistry and new plate technology our PWL battery
has increased life to 10-13 years at +25C; roughly 4 times the life of
conventional batteries. Long life means longer backup times and lower
maintenance cost.
PWL Series Line Card
| Model | Spec. Sheet | NOMINAL VOLTAGE (V) |
Rated Capacity (AH) at 20 hr rate |
DIMENSIONS | WEIGHT | |||
| millimeters | kg | |||||||
| L | W | H | TH | |||||
| PWL Series | Super Long Life Type | |||||||
| PWL12V7 | 12 | 7 | 151.0 | 65.0 | 94.0 | 98.0 | 3.00 | |
| PWL12V24 | 12 | 24 | 166.0 | 125.0 | 175.0 | 8.90 | ||
| PWL12V28 | 12 | 28 | 166.0 | 125.0 | 175.0 | 175.0 | 9.00 | |
| PWL12V38 | 12 | 38 | 196.0 | 163.0 | 174.0 | 174.0 | 14.00 | |
| PWL12V100 | 12 | 100 | 407.0 | 173.0 | 210.0 | 233.0 | 36.00 | |
| PWL12V100FT | 12 | 100 | 558.0 | 125.0 | 230.0 | 214.0 | 40.00 | |
| PWL12V125FT | 12 | 125 | 558.0 | 125.0 | 276.0 | 260.0 | 50.00 | |
| PWL12V125FS |
|
12 | 125 | 417.0 | 176.0 | 255.0 | 255.0 | 50.00 |
Battery Performance Specifications
| PWL12V7 | Amperes to Final Volts per Cell | |||||||||||
| Temp. | 25 º C (77 º F) | |||||||||||
| Discharge Time (Hr) | ||||||||||||
| F.V. | 20 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0.5 |
| 1.60 | 0.37 | 0.67 | 0.73 | 0.80 | 0.90 | 1.0 | 1.2 | 1.4 | 1.8 | 3.0 | 4.5 | 7.4 |
| 1.70 | 0.36 | 0.64 | 0.71 | 0.78 | 0.87 | 0.99 | 1.2 | 1.4 | 1.8 | 2.9 | 4.3 | 7.1 |
| 1.80 | 0.34 | 0.60 | 0.65 | 0.72 | 0.81 | 0.92 | 1.1 | 1.3 | 1.6 | 2.7 | 4.0 | 6.7 |
| 1.90 | 0.29 | 0.52 | 0.57 | 0.62 | 0.69 | 0.79 | 0.92 | 1.1 | 1.4 | 2.3 | 3.4 | 5.6 |
| PWL12V28 | Amperes to Final Volts per Cell | |||||||||||
| Temp. | 25 º C (77 º F) | |||||||||||
| Discharge Time (Hr) | ||||||||||||
| F.V. | 20 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0.5 |
| 1.60 | 1.5 | 2.7 | 2.9 | 3.2 | 3.6 | 4.1 | 4.7 | 5.7 | 7.3 | 11.8 | 18.1 | 29.8 |
| 1.70 | 1.5 | 2.6 | 2.8 | 3.1 | 3.5 | 3.9 | 4.6 | 5.5 | 7.1 | 11.5 | 17.3 | 28.6 |
| 1.80 | 1.3 | 2.4 | 2.6 | 2.9 | 3.2 | 3.7 | 4.3 | 5.1 | 6.5 | 10.6 | 16.2 | 26.7 |
| 1.90 | 1.2 | 2.1 | 2.3 | 2.5 | 2.8 | 3.2 | 3.7 | 4.4 | 5.6 | 9.0 | 13.7 | 22.4 |
| PWL12V38 | Amperes to Final Volts per Cell | |||||||||||
| Temp. | 25 º C (77 º F) | |||||||||||
| Discharge Time (Hr) | ||||||||||||
| F.V. | 20 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0.5 |
| 1.60 | 2.0 | 3.6 | 4.0 | 4.3 | 4.9 | 5.5 | 6.4 | 7.8 | 9.8 | 16.0 | 24.5 | 40.4 |
| 1.70 | 2.0 | 3.5 | 3.8 | 4.2 | 4.7 | 5.4 | 6.3 | 7.5 | 9.6 | 15.7 | 23.4 | 38.8 |
| 1.80 | 1.8 | 3.2 | 3.5 | 3.9 | 4.4 | 5.0 | 5.8 | 7.0 | 8.9 | 14.4 | 22.0 | 36.2 |
| 1.90 | 1.6 | 2.8 | 3.1 | 3.4 | 3.8 | 4.3 | 5.0 | 6.0 | 7.6 | 12.3 | 18.7 | 30.4 |
| PWL12V100 | Amperes to Final Volts per Cell | |||||||||||
| Temp. | 25 º C (77 º F) | |||||||||||
| Discharge Time (Hr) | ||||||||||||
| F.V. | 20 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0.5 |
| 1.60 | 5.58 | 9.99 | 10.9 | 12.1 | 13.6 | 15.5 | 18.0 | 21.6 | 27.2 | 38.1 | 66.6 | 116 |
| 1.70 | 5.40 | 9.90 | 10.8 | 11.9 | 13.3 | 15.1 | 17.6 | 21.2 | 26.3 | 36.5 | 63.0 | 108 |
| 1.80 | 5.13 | 9.36 | 10.2 | 11.2 | 12.6 | 14.5 | 16.7 | 19.9 | 24.5 | 33.8 | 56.7 | 94.5 |
| 1.90 | 4.5 | 8.46 | 9.27 | 10.4 | 11.3 | 13.1 | 15.5 | 18.0 | 22.3 | 30.1 | 49.1 | 79.5 |
| PWL12V100FT | Amperes to Final Volts per Cell | ||||||||||
| Temp. | 25 º C (77 º F) | ||||||||||
| Discharge Time (Hr) | |||||||||||
| F.V. | 20 | 12 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 |
| 1.75 | 5.42 | 8.85 | 10.4 | 11.5 | 12.5 | 13.9 | 15.5 | 18.0 | 21.4 | 26.8 | 36.2 |
| 1.80 | 5.25 | 8.44 | 10.1 | 11.1 | 12.4 | 13.6 | 15.4 | 17.6 | 20.9 | 26.0 | 35.6 |
| 1.85 | 4.87 | 8.16 | 9.75 | 10.6 | 11.7 | 12.9 | 14.6 | 16.9 | 20.1 | 24.9 | 33.8 |
| PWL12V125FT | Amperes to Final Volts per Cell | ||||||||||
| Temp. | 25 º C (77 º F) | ||||||||||
| Discharge Time (Hr) | |||||||||||
| F.V. | 20 | 12 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 |
| 1.75 | 7.11 | 11.0 | 12.9 | 14.1 | 15.6 | 17.5 | 20.0 | 23.4 | 28.4 | 36.3 | 51.4 |
| 1.80 | 6.90 | 10.7 | 12.4 | 13.6 | 15.0 | 16.9 | 19.1 | 22.4 | 27.1 | 34.5 | 48.8 |
| 1.85 | 6.64 | 10.2 | 11.8 | 12.9 | 14.2 | 15.9 | 18.2 | 21.1 | 25.4 | 32.4 | 45.4 |