Rechargeable Valve Regulated Sealed Lead Acid (VRLA) Battery
PXL 12072F1VO Specifications
1 Nominal Voltage 12V
2 Nominal Capacity

at 20 hour rate

at 10 hour rate

at 5 hour rate

at 3 hour rate

at 1 hour rate

at 30 minute rate

at 15 minute rate

7.2Ah, 0.36A, FV=10.5V

6.5Ah, 0.65A, FV=10.5V

6.1Ah, 1.22A, Fv=10.5V

5.04Ah, 1.68A, FV=10.2V

4.32Ah, 4.32A, FV=9.6V

3.8Ah, 7.6A, FV=9.0V

2.88Ah, 11.52A, FV=9.0V

3 Weight (Approx.) 5.95 lbs. (2,700 grams)
4 Internal Resistance of fully charged battery 13 milliohms
5 Energy Density (0.05C) 1.53 Watt-hours/cubic inch (93.6 Watt-hours/)
6 Specific Energy (0.05C) 14.5 Watt-hours/pound (32.0 Watt-hours/kg)
7 Maximum Discharge Current with standard terminals 43.2 amperes
8 Maximum Short Duration Discharge Current (less than 5 sec.) 108 amperes
9 Vibration Test

No loss in capacity or performance

(2000 cycles/minute, 0.10 inch excursion, 2 hours)

10 Charge Retention (shelf life) % of nominal capacity at 77ºF (25ºC)

1 month 97%
3 months 91%
6 months 82%

11 Operating Temperature Range Charge 32ºF (0ºC) to 122ºF (50ºC)
Discharge -4ºF (-20ºC) to 122ºF (50ºC)
Storage -4ºF (-20ºC) to 104ºF (40ºC)
12 Case Material UL94 V-O "flame retardant" resin   * Optional: Synthetic resin (ABS)
13 Standard Terminal F1: AMP Faston Type 187
14 Dimensions

length: 5.94 +/- 0.04 inches (151.0 +/- 1.0 mm)

width: 2.56 +/- 0.04 inches (65.0 +/- 1.0 mm)

height:  with terminal, 3.86 +/ - 0.08 inches (98.0 +/- 2.0 mm)

               w/out 3.70 +/- 0.08 inches (94.0 +/- 2.0 mm)

CHARGING METHODS

CYCLIC USE:
Maximum Initial Charge Current: 650mA

Charging Voltage: 14.4V-14.7V
Charge should be switched to float mode or disconnected when current drops to 26mA

STANDBY USE:
Maximum Initial Charge Current: 650mA

Charge Voltage: 13.5V-13.8V

Copyright © 2004 GS Battery (USA) Inc. All rights reserved